[vhdl-200x-ft] Re: ISAC issue

From: Jim Lewis <Jim@SynthWorks.com>
Date: Tue Nov 09 2004 - 07:47:57 PST

Zeev,
Good point. Looks like an ISAC issue. ISAC handles
issues with correctness of the current standard.

In the future you can submit bugs and enhancement
requests at:
   http://www.eda-twiki.org/vasg/bugrep.htm

or it is available through the "Enhancement Request"
link at:
   http://www.eda-twiki.org/vhdl-200x/

Regards,
Jim

-------- Original Message --------
From: "Zeev Lazarev" <layigal@interal.co.il>
To: <vhdl-200x-ft@server.eda.org>
Subject: vhdl-200x issue
Date: Tue, 9 Nov 2004 15:50:52 +0200

Clause '13.3.2 Extended identifiers', second paragraph.
The sentence is read as follows:

If a backslash is to be used as one of the graphic characters of an
extended literal, it must be doubled.

My proposal is to change the 'extended literal' to 'extended identifier'
to reflect the sense of discussed subject, so the final sentence will read
as follows:

If a backslash is to be used as one of the graphic characters of an
extended identifier, it must be doubled.

--
Zeev L.
Received on Tue Nov 9 07:48:01 2004

This archive was generated by hypermail 2.1.8 : Tue Nov 09 2004 - 07:48:38 PST